142 Storage Management Message Reference
2170 The
controller
battery
charge level
is normal.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1151
2171 The
controller
battery
temperature
is above
normal.
Warning /
Non-critical
Cause: The battery may
be recharging, the room
temperature may be too
hot, or the fan in the
system may be degraded
or failed.
Action: If this alert was
generated due to a
battery recharge, the
situation will correct
when the recharge is
complete. You should
also check if the room
temperature is normal
and that the system
components are
functioning properly.
Clear Alert
Number:
2172.
Related Alert
Number:
None.
LRA Number:
2100
1153
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vue de la page 141