188 Storage Management Message Reference
2293 The EMM
has failed.
Critical /
Failure / Error
Cause: The failure may
be caused by a loss of
power to the EMM.
The EMM self test may
also have identified a
failure. There could also
be a firmware problem
or a multi-bit error.
Action: Replace the
EMM. See the hardware
documentation for
information on
replacing the EMM.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2091
854 and
954
2294 A device has
been
inserted.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1001
and
1101
2295 A device has
been
removed.
Critical /
Failure / Error
Cause: A device has
been removed and the
system is no longer
functioning in optimal
condition.
Action: Replace the
device.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2091
1004
and
1104
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vue de la page 187