68 System Event Log Messages for IPMI Systems
Intrusion Events
The chassis intrusion messages are a security measure. Chassis intrusion
alerts are generated when the system's chassis is opened. Alerts are sent to
prevent unauthorized removal of parts from the chassis.
Drive
<Drive #>
in critical array was
asserted
Critical This event is generated
when the drive is placed in
critical array.
Drive
<Drive #>
in critical array was
deasserted
Informational This event is generated
when the drive is removed
from critical array.
Drive
<Drive #>
in failed array was asserted
Critical This event is generated
when the drive is placed in
the fail array.
Drive
<Drive #>
in failed array was
deasserted
Informational This event is generated
when the drive is removed
from the fail array.
Drive
<Drive #>
rebuild in progress was
asserted
Informational This event is generated
when the drive is
rebuilding.
Drive
<Drive #>
rebuild aborted was asserted
Warning This event is generated
when the drive rebuilding
process is aborted.
Table 3-11. Intrusion Events
Event Message Severity Cause
<Intrusion sensor
Name> sensor detected
an intrusion.
Critical This event is generated when the
intrusion sensor detects an intrusion.
<Intrusion sensor
Name> sensor returned
to normal state.
Information This event is generated when the
earlier intrusion has been corrected.
Table 3-10. Drive Events (continued)
Event Message Severity Cause