202 Storage Management Message Reference
2320 Single-bit
ECC error.
The DIMM
is critically
degraded.
Critical /
Failure / Error
Cause: The DIMM is
malfunctioning.
Data loss or data
corruption may be
imminent.
Action: Replace the
DIMM immediately to
avoid data loss or data
corruption. The DIMM
is a part of the
controller battery pack.
See your hardware
documentation for
information on
replacing the DIMM or
contact technical
support.
Clear Alert
Number:
None.
Related Alert
Number: 2321
LRA Number:
2061
754
2321 Single-bit
ECC error.
The DIMM
is critically
degraded.
There will be
no further
reporting.
Critical /
Failure / Error
Cause: The DIMM is
malfunctioning.
Data loss or data
corruption is imminent.
The DIMM must be
replaced immediately.
No further alerts will be
generated.
Action: Replace the
DIMM immediately.
The DIMM is a part of
the controller battery
pack. See your hardware
documentation for
information on
replacing the DIMM.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2061
754
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers