18
Fixed problems
EMC AX4-5 Series Integrated Management Software Release Notes
Platforms Brief description Symptom details
Solution (or
workaround)
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
AX4-5SCF4
AX4-5F8
FLARE Operating
Environment
An enclosure may be reported
as faulted after an LCC is
replaced.
231405
Frequency of occurrence
:
Rarely under a specific set of
circumstances.
Severity
:
Medium
An enclosure may be
reported as faulted after an
LCC is replaced.
KnowledgeBase ID
:
None
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
02.23.050.5.705
Fixed in version
:
02.23.050.5.707
AX4-5i
AX4-5SCi
FLARE Operating
Environment
On an AX4-5i or AX4-5SCi,
storage processor bugchecks
(0x000000D1) may occur when
a host accesses a LUN.
31485584/238188
Frequency of occurrence
:
Always under a rare set of
circumstances.
Severity
:
Critical
On an AX4-5i or AX4-
5SCi, storage processor
bugchecks (0x000000D1)
will occur if a host uses an
unsupported address
method to access a LUN.
KnowledgeBase ID
:
None
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
02.23.050.5.705
Fixed in version
:
02.23.050.5.707
Problems fixed in version 02.23.050.5.705
Platforms Brief description Symptom details
Solution (or
workaround)
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
FLARE Operating
Environment
A single storage processor
bugcheck (0x008000f1) may
occur when a hot spare is
swapped in.
23569238/200490
Frequency of occurrence
:
Rarely under a specific set of
circumstances.
Severity
:
Medium
A single storage processor
bugcheck (0x008000f1)
may occur when a hot
spare is swapped in for a
drive, if a trespass is in
progress for one of the
LUNs on that drive.
KnowledgeBase ID
:
None
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
Fixed in version
:
02.23.050.5.705