Dell Networking S6000
Installation Guide
Publication Date: October 2013
Vue de la page 0
1 2 3 4 5 6 ... 55 56

Résumé du contenu

Page 1 - Installation Guide

Dell Networking S6000Installation GuidePublication Date: October 2013

Page 2 - Notes, Cautions, and Warnings

10 | The S6000 Systemwww.dell.com | support.dell.comFigure 2-2. S6000 I/O-Side View1 - System LED2 - 32 QSFP+ Ports3 - Serial Console4 - Reset5 - Sta

Page 3 - Contents

The S6000 System | 11• Temperature monitoring• Software-readable thermal monitor• Real time clock (RTC) support• Hot-plugging redundant power supply•

Page 4 - 9 Technical Support

12 | The S6000 Systemwww.dell.com | support.dell.comFigure 2-3. PSU and Fan Tray LEDs1- Fan Tray 0-2 LEDs2 - PSU 0-1 LEDs1 - Serial Console2 - Master

Page 5

The S6000 System | 13 NOTE: When one of the FAN LEDs on the utility side indicates failure, the fan LED on the I/O panel displays yellow.The S6000 sup

Page 6

14 | The S6000 Systemwww.dell.com | support.dell.comTable 2-2. 40G QSFP+/ 4x10G SFP+ Ethernet Port LEDsTable 2-3. Management Ethernet Port LEDsBasic

Page 7 - About this Guide

The S6000 System | 15Orderable S6000 ComponentsYou can order the S6000 system in several different configurations. Also, you can order optional module

Page 8 - 8

16 | The S6000 Systemwww.dell.com | support.dell.com

Page 9 - The S6000 System

Site Location and Preparation | 173Site Location and PreparationThe S6000 is suitable for installation as part of a common bond network (CBN). It can

Page 10 - Features

18 | Site Location and Preparationwww.dell.com | support.dell.comSite SelectionDell Network’s equipment is intended for installation in restricted acc

Page 11 - LED Displays

Site Location and Preparation | 19Fan CombinationsThe S6000 has stock keeping units (SKUs) that support the following configurations. Installation of

Page 12 - 12

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indica

Page 13 - The S6000 System

20 | Site Location and Preparationwww.dell.com | support.dell.comFollow these storage guidelines:• Storage temperature must remain constant ranging fr

Page 14 - Link on 10/100M/1G speed

Install the S6000 | 214Install the S6000To install the S6000 system, Dell Networking recommends completing the installation procedures in the order pr

Page 15 - Orderable S6000 Components

22 | Install the S6000www.dell.com | support.dell.com• If an AC switch, at least one AC power cord (country/region specific)• If a DC switch, at least

Page 16 - 16

Install the S6000 | 23• Reduced air flow — Install the equipment in the rack so that the amount of airflow required for safe operation of the equipmen

Page 17 - Site Location and Preparation

24 | Install the S6000www.dell.com | support.dell.comConfiguring a Two-Post Flush-MountStep Task1 For this configuration, remove the castings from the

Page 18 - Fans and Airflow

Install the S6000 | 25Configuring a Two-Post Center-MountStep Task1 Slide the plunger bracket rearward until it clicks into place and secure the brack

Page 19 - Storing Components

26 | Install the S6000www.dell.com | support.dell.comConfigure a Four-Post ThreadStep Task1 For this configuration, remove the flange ear castings fro

Page 20

Install the S6000 | 27Installing the S6000 SystemYou can mount the system in the 1U front-rack or 1U two-post (flush and center) configurations. The f

Page 21 - Install the S6000

28 | Install the S6000www.dell.com | support.dell.comAttaching the Ground CableTo attach the ground cable to the chassis, use a single M4x0.7 screw. T

Page 22 - 22

Install the S6000 | 29Installing an AC or DC Power SupplyThe S6000 supports two hot-swappable PSUs with integrated fans that provide cooling for the s

Page 23 - Step Task

| 3Contents1 About this GuideRelated Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24 - 24

30 | Install the S6000www.dell.com | support.dell.com NOTE: S6000 ships with two PSUs. However, it is possible to run the unit with a single PSU. If y

Page 25 - Install the S6000

Install the S6000 | 31Installing QSFP+ OpticsThe S6000 has 32 40Gbps QSFP+ optical ports. WARNING: ESD damage can occur if components are mishandled.

Page 26 - Configure a Four-Post Thread

32 | Install the S6000www.dell.com | support.dell.com• For the split-port change to take effect, you must reload the system after issuing the command.

Page 27 - Installing the S6000 System

Power Supplies | 335Power SuppliesThe S6000 supports two hot-swappable PSUs with integrated fans that provide cooling for the system. The S6000 suppor

Page 28

34 | Power Supplieswww.dell.com | support.dell.comThe PSUs are in a single piece with the PSU fans (see Figure 5-1). You can replace the fan trays ind

Page 29

Power Supplies | 35Replacing an AC or DC Power Supply Caution: Disconnect power cord before removing power supplies and disconnect all power cords be

Page 30 - 30

36 | Power Supplieswww.dell.com | support.dell.comFigure 5-2. DC Power Connector and Wiring BlockTo connect a S6000 DC PSU to the site’s DC power sou

Page 31 - Installing QSFP+ Optics

Fans | 376FansThe S6000 comes from the factory with two PSUs and three fan modules installed in the chassis (see Figure 6-1). The S6000 has SKUs that

Page 32 - Power Up the S6000 System

38 | Fanswww.dell.com | support.dell.comInstalling a Fan ModuleThe fan modules in the S6000 are field replaceable. Module slot 0 is on the left side o

Page 33 - Power Supplies

Management Ports | 397Management PortsBesides the 10 Gigabit and 40 Gigabit switch ports, the S6000 provides several ports for management and storage.

Page 34

4 |www.dell.com | support.dell.comSplit QSFP+ Ports to SFP+ Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Important P

Page 35 - Figure 5-2

40 | Management Portswww.dell.com | support.dell.comAccessing the USB-B Console PortThe terminal settings are the same for the USB-B port and the cons

Page 36

Management Ports | 41 NOTE: Before starting this procedure, be sure you have a terminal emulation program already installed on your PC. You will need

Page 37 - Components

42 | Management Portswww.dell.com | support.dell.com

Page 38 - Replacing a Fan Module

Specifications | 438SpecificationsThis chapter contains the following sections:• Chassis Physical Design• Environmental Parameters• Power Requirements

Page 39 - Management Ports

44 | Specificationswww.dell.com | support.dell.comPower RequirementsThe following tables represent the PSU’s capabilities and do not represent the S60

Page 40 - Step Task (continued)

Specifications | 45• 802.3ba 40 Gigabit Ethernet (40GBase-SR4, 40GBase-CR4) on optical ports• 802.3u Fast Ethernet (100BASE-TX)• 802.3x Flow Control•

Page 41 - Default Configuration

46 | Specificationswww.dell.com | support.dell.comCanadian Department of Communication Statement European Union EMC Directive Conformance StatementThi

Page 42 - 42

Specifications | 47Korean Certification of ComplianceKorean Package LabelSafety Standards and Compliance Agency Certifications• CUS UL 60950-1, 2nd Ed

Page 43 - Specifications

48 | Specificationswww.dell.com | support.dell.comElectromagnetic Compatibility (EMC)Emissions• International: CISPR 22: 2006, Class A• Australia/New

Page 44 - IEEE Standards

Specifications | 49Figure 8-1. The European WEEE symbolIn accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is t

Page 45 - Agency Compliance

| 5The iSupport Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Accessing iSupport Services

Page 46 - 46

50 | Specificationswww.dell.com | support.dell.com

Page 47 - Korean Package Label

Technical Support | 519Technical Support This chapter contains the following sections:• The iSupport Website• Contacting the Technical Assistance Cent

Page 48 - Telecommunications Products

52 | Technical Supportwww.dell.com | support.dell.comContacting the Technical Assistance CenterHow to Contact Dell Networking TACLog in to iSupport at

Page 49 - Specifications

Technical Support | 53Requesting a Hardware ReplacementTo request replacement hardware, follow these steps:Step Task 1 Determine the part number and s

Page 50 - 50

54 | Technical Supportwww.dell.com | support.dell.com

Page 52

www.dell.com | support.dell.comPrinted in the U.S.A.

Page 53 - Technical Support

6 |www.dell.com | support.dell.com

Page 54 - 54

About this Guide | 71About this GuideThis guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting

Page 55

8 | About this Guidewww.dell.com | support.dell.com

Page 56 - Printed in the U.S.A

The S6000 System | 92The S6000 SystemThis chapter contains general features, capabilities, and physical configurations the S6000 supports. Introductio