Dell EMC AX4-5 Guide d'installation Page 21

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 47
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 20
21
Fixed problems
EMC AX4-5 Series Integrated Management Software Release Notes
Platforms Brief description Symptom details
Solution (or
workaround)
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
FLARE Operating
Environment
Hosts attempting to boot their
operating system over iSCSI
from the storage system may
fail.
213662
Frequency of occurrence
:
Likely under a rare set of
circumstances.
Severity
:
Critical
Hosts attempting to boot
their operating system
over iSCSI from the
storage system may fail
due to too many login
sessions.
KnowledgeBase ID
:
None
Fixed in code
Exists in versions:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
Fixed in version
:
02.23.050.5.705
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
FLARE Operating
Environment
Single-SP panic occurs when
I/O is running if write-aside
value is set low.
184973
Frequency of occurrence
:
Rarely under a specific set of
circumstances
Severity
:
Medium
Single-SP panic occurs
when I/O is running if the
write-aside value is set
below the default value
and trespassing is
occurring.
KnowledgeBase ID
:
None
Fixed in code
Exists in versions:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
Fixed in version:
02.23.050.5.705
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
FLARE Operating
Environment
A single storage processor
bugcheck (0x00000001) may
occur.
25455418/208005
Frequency of occurrence
:
Rarely under a rare set of
circumstances.
Severity
:
Medium
A single storage processor
bugcheck (0x00000001)
may occur after several
months of uptime.
KnowledgeBase ID
:
None
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
Fixed in version
:
02.23.050.5.705
Vue de la page 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 46 47

Commentaires sur ces manuels

Pas de commentaire