Vue de la page 190
Using the Storage Management Service 189
Example for SCSI, SATA, and ATA Controllers
To enable the alarm on the enclosure attached to connector 2 on controller 1,
enter:
omconfig storage enclosure action=enablealarm
controller=1 enclosure=2
Example for SAS Controllers
To enable the alarm on enclosure 2 attached to connector 1 on controller 1,
enter:
omconfig storage enclosure action=enablealarm
controller=1 enclosure=1:2
omconfig Disable Enclosure Alarm
Use the following omconfig command syntax to disable the enclosure alarm.
Complete Syntax
omconfig storage enclosure action=disablealarm
controller=id enclosure=<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the
enclosure.
Example for SCSI, SATA, and ATA Controllers
To disable the alarm on the enclosure attached to connector 2 on controller 1,
enter:
omconfig storage enclosure action=disablealarm
controller=1 enclosure=2
Example for SAS Controllers
To disable the alarm on enclosure 2 attached to connector 1 on controller 1,
enter:
omconfig storage enclosure action=disablealarm
controller=1 enclosure=1:2