Dell OpenManage Server Administrator Version 5.5 Guide de l'utilisateur Page 109

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 238
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 108
Storage Management Message Reference 109
2107 Smart
configuration
change
Critical /
Failure /
Error
Cause: A disk has received
a SMART alert (predictive
failure) after a
configuration change.
The disk is likely to fail in
the near future.
Action: Replace the disk
that has received the
SMART alert. If the
physical disk is a member
of a non-redundant virtual
disk, then back up the data
before replacing the disk.
NOTICE: Removing
a physical disk that
is included in a
non-redundant virtual
disk will cause the
virtual disk to fail and
may cause data loss.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2071
904
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vue de la page 108