Storage Management Message Reference 181
2289 Multi-bit
ECC error.
Critical /
Failure /
Error
Cause: An error involving
multiple bits has been
encountered during a read
or write operation. The
error correction algorithm
recalculates parity data
during read and write
operations. If an error
involves only a single bit, it
may be possible for the
error correction algorithm
to correct the error and
maintain parity data. An
error involving multiple
bits, however, usually
indicates data loss. In some
cases, if the multi-bit error
occurs during a read
operation, the data on the
disk may be correct/valid. If
the multi-bit error occurs
during a write operation,
data loss has occurred.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2061
754
Action: Replace the dual
in-line memory module
(DIMM). The DIMM is a
part of the controller
battery pack. See your
hardware documentation
for information on
replacing the DIMM. You
may need to restore data
from backup.
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vue de la page 180