Vue de la page 174
Storage Management Message Reference 175
2274 The physical
disk rebuild
has
resumed.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
901
2276 The
dedicated
hot spare is
too small.
Warning /
Non-
critical
Cause: The dedicated hot
spare is not large enough to
protect all virtual disks that
reside on the disk group.
Action: Assign a larger disk
as the dedicated hot spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
2277 The global
hot spare is
too small.
Warning /
Non-
critical
Cause: The global hot spare
is not large enough to
protect all virtual disks that
reside on the controller.
Action: Assign a larger disk
as the global hot spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)