Dell OpenManage Server Administrator Version 5.5 Guide de l'utilisateur Page 117

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 238
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 116
Storage Management Message Reference 117
2120 Enclosure
firmware
mismatch
Warning /
Non-
critical
Cause: The firmware on
the EMM is not the same
version. It is required that
both modules have the
same version of the
firmware. This alert may be
caused when a user
attempts to insert an EMM
module that has a different
firmware version than an
existing module.
Action: Download the
same version of the
firmware to both EMM
modules.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2090
853
2121 Device
returned to
normal
OK /
Normal
Cause: This alert is for
informational purposes. A
device that was previously
in an error state has
returned to a normal state.
For example, if an
enclosure became too hot
and subsequently cooled
down, then you may
receive this alert.
Action: None
Clear Alert
Status: Alert
2121 is a clear
alert for alert
2048.
Related Alert
Number: 2050,
2065, 2158
LRA Number:
None.
752
802
852
902
952
1002
1052
1102
1152
1202
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vue de la page 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 237 238

Commentaires sur ces manuels

Pas de commentaire