38 Event Message Reference
1301 Redundancy sensor
value unknown
Redundancy unit:
<Redundancy location
in chassis>
Chassis location:
<Name of chassis>
Previous redundancy
state was:
<State>
Information A redundancy sensor in the
specified system could not
obtain a reading.
The redundancy unit location,
chassis location, previous
redundancy state, and the
number of devices required
for full redundancy
are provided.
1302 Redundancy not
applicable
Redundancy unit:
<Redundancy location
in chassis>
Chassis location:
<Name of chassis>
Previous redundancy
state was:
<State>
Information A redundancy sensor in the
specified system detected
that a unit was not redundant.
The redundancy location,
chassis location, previous
redundancy state, and the
number of devices required
for full redundancy are
provided.
1303 Redundancy is offline
Redundancy unit:
<Redundancy location
in chassis>
Chassis location:
<Name of chassis>
Previous redundancy
state was:
<State>
Information A redundancy sensor in the
specified system detected that
a redundant unit is offline.
The redundancy
unit location, chassis location,
previous redundancy state,
and the number of devices
required for full redundancy
are provided.
Table 2-8. Redundancy Unit Messages (continued)
Event
ID
Description Severity Cause
Vue de la page 37