Error Code Message Information
Details Fan has failed.
Action Remove and reinstall failed fans or install additional fans.
HWC1001
Message The <
name
> is absent.
LCD Message The <
name
> is absent. Check hardware.
Details The absent device may be necessary for proper operation. System functionality may be
degraded.
Action Reinstall or reconnect the hardware.
HWC2003
Message The storage <
name
> cable is not connected, or is improperly connected.
LCD Message Storage <
name
> cable or interconnect failure. Check connection.
Details The cable may be necessary for proper operation. System functionality may be
degraded.
Action Check if the cable is present, then reinstall or reconnect.
HWC2005
Message The system board <
name
> cable is not connected, or is improperly connected.
LCD Message System board <
name
> cable connection failure. Check connection.
Details The cable may be necessary for proper operation. System functionality may be
degraded.
Action Check if the cable is present, then reinstall or reconnect.
MEM0000
Message Persistent correctable memory errors detected on a memory device at location(s)
<
location
>.
Details This is an early indicator of a possible future uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help .
MEM0001
Message Multi-bit memory errors detected on a memory device at location(s) <
location
>.
LCD Message Multi-bit memory error on <
location
>. Re-seat memory.
Details The memory module has encountered an uncorrectable error. System performance
may be degraded. The operating system and/or applications may fail as a result.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0007
Message Unsupported memory configuration; check memory device at location <
location
>.
LCD Message Unsupported memory configuration. Check memory <
location
>.
Details The memory may not be seated correctly, misconfigured, or has failed. Memory size is
reduced.