Dell EMC AX4-5 Guide d'installation Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 47
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
11
Fixed problems
EMC AX4-5 Series Integrated Management Software Release Notes
Platforms Brief description Symptom details
Solution (or
workaround)
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
AX4-5SCF4
AX4-5F8
FLARE Operating
Environment
Standby power supply (SPS)
cabling status can be
incorrectly marked as faulted if
an SPS transitions to battery-
on-line while being tested.
240286
Frequency of occurrence
:
Always under a rare set of
circumstances
Severity
:
Low
Standby power supply
(SPS) cabling status can
be incorrectly marked as
faulted if an SPS
transitions to battery-on-
line while being tested.
KnowledgeBase ID
:
None
Fixed in code.
Exists in versions:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
02.23.050.5.705
02.23.050.5.707
Fixed in version
:
02.23.050.5.709
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
AX4-5SCF4
AX4-5F8
FLARE Operating
Environment
If a hot spare drive fails after it
has been swapped in for a
failed drive in a RAID group, it
may not be swapped out.
32476378/245009
Frequency of occurrence
:
Always under a rare set of
circumstances.
Severity
:
Medium
If a hot spare drive fails
after it has been swapped
in for a failed drive in a
RAID group, it may not be
swapped out. Rebuilds will
not resume if the hot spare
is replaced, or if the
original failed drive in the
RAID group is replaced.
This happens when a
RAID group expansion or
defragmentation operation
had previously been
performed on the RAID
group with the failed drive.
KnowledgeBase ID
:
None
Fixed in code.
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
02.23.050.5.705
02.23.050.5.707
Fixed in version
:
02.23.050.5.709
Vue de la page 10