Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guide de l'utilisateur Page 103

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 292
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 102
Storage Management Message Reference 103
2110 SMART
warning
degraded
Warning /
Non-critical
Cause: A disk is
degraded and has
received a SMART alert
(predictive failure). The
disk is likely to fail in
the near future.
Action: Replace the
disk that has received
the SMART alert. If the
physical disk is a
member of a non-
redundant virtual disk,
then back up the data
before replacing the
disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk causes the virtual
disk to fail and may
cause data loss.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2070
903
2111 Failure
prediction
threshold
exceeded due
to test
Warning /
Non-critical
Cause: A disk has
received a SMART alert
(predictive failure) due
to test conditions.
Action: None
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2070
903
Table 3-4. Storage Management Messages