224 Storage Management Message Reference
2384 The Warning
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
Warning /
Non-critical
Cause: The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action: Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
2195
Related
Alert: None
LRA
Number:
None
1203
2385 The Critical
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
Critical /
Failure / Error
Cause: The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action: Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
2195
Related
Alert: None
LRA
Number:
None
1204
2386 The drive
could not be
assigned as a
Dedicated Hot
Spare.
Warning /
Non-critical
Cause: The assignment
of a Dedicated Hot
Spare fails as the disk is
invalid.
Action: None
Clear Alert:
2195
Related
Alert: None
LRA
Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vue de la page 223