26 Server Management Messages
Cooling Device Messages
The cooling device sensors listed in Table 2-3 monitor how well a fan is
functioning. Cooling device messages provide status and warning information
for fans in a particular chassis.
Table 2-3. Cooling Device Messages
Event
ID
Description Severity Cause
1100 Fan sensor has failed
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Error A fan sensor in the
specified system is
not functioning.
The sensor
location, chassis
location, previous
state, and fan
sensor value
information is
provided.
1101 Fan sensor value unknown
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Error A fan sensor in the
specified system
could not obtain a
reading. The sensor
location, chassis
location, previous
state, and a
nominal fan sensor
value information
is provided.