Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guide de l'utilisateur Page 33

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 292
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 32
Server Management Messages 33
1201 Current sensor value unknown
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading> OR
Current sensor value (in
Watts): <Reading>
If sensor type is discrete:
Discrete current state: <State>
Error A current sensor
in the specified
system could not
obtain a reading.
The sensor
location, chassis
location, previous
state, and a
nominal current
sensor value
information is
provided.
1202 Current sensor returned to
a normal value
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading> OR
Current sensor value (in
Watts): <Reading>
If sensor type is discrete:
Discrete current state: <State>
Information A current sensor
in the specified
system returned
to a valid range
after crossing a
failure threshold.
The sensor
location, chassis
location, previous
state, and current
sensor value
information is
provided.
Table 2-5. Current Sensor Messages
(continued)
Event
ID
Description Severity Cause