Storage Management Message Reference 93
2099 Global hot
spare
unassigned
OK / Normal /
Informational
Cause: A physical disk
that was assigned as a
hot spare has been
unassigned and is no
longer functioning as a
hot spare. The physical
disk may have been
unassigned by a user or
automatically
unassigned by Storage
Management. Storage
Management unassigns
hot spares that have
been used to rebuild
data. Once data is
rebuilt, the hot spare
becomes a member of
the virtual disk and is
no longer assigned as a
hot spare. You need to
assign a new hot spare
to maintain data
protection in this
situation. On the
CERC SATA1.5/6ch,
and CERC SATA1.5/2s
controllers, if you use
another application
such as the BIOS to
include a hot spare in a
virtual disk, then
Storage Management
unassigns the physical
disk as a hot spare.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vue de la page 92