Storage Management Message Reference 137
2174 The controller
battery has
been removed.
Warning /
Non-critical
Cause: The controller
cannot communicate
with the battery. The
battery may be
removed, or the contact
point between the
controller and the
battery may be burnt or
corroded.
Action: Replace the
battery if it has been
removed. If the contact
point between the
battery and the
controller is burnt or
corroded, you must
replace either the
battery or the controller,
or both. See the
hardware
documentation for
information on how to
safely access, remove,
and replace the battery.
Clear Alert:
None
Related
Alert
Number:
2188, 2318
LRA
Number:
2100
1153
2175 The controller
battery has
been replaced.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1151
Table 3-4. Storage Management Messages