Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guide de l'utilisateur Page 219

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 292
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 218
Storage Management Message Reference 219
2369 Virtual Disk
Redundancy
has been
degraded.
OK / Normal /
Informational
Cause: A physical disk
in a RAID 6 virtual disk
has either failed or been
removed.
Action: Replace the
missing or failed
physical disk.
Clear Alert
Number:
2121
Related
Alert
Number:
2048, 2049,
2050, 2076,
2346
LRA
Number:
None
1201
2370 Redundant
Path View
cleared
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1201
2371 Attempted
import of
Unsupported
Virtual Disk
type RAID%1
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
751
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vue de la page 218
1 2 ... 214 215 216 217 218 219 220 221 222 223 224 ... 291 292

Commentaires sur ces manuels

Pas de commentaire