142 Storage Management Message Reference
2186 The controller
cache has been
discarded.
Warning /
Non-critical
Cause: The controller
has flushed the cache
and any data in the
cache has been lost.
This may happen if the
system has memory or
battery problems that
cause the controller to
distrust the cache.
Although user data may
have been lost, this alert
does not always indicate
that relevant or user data
has been lost.
Action: Verify that the
battery and memory are
functioning properly.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2060
753
2187 Single-bit
ECC error
limit exceeded
on the
controller
DIMM.
Warning /
Non-critical
Cause: The system
memory is
malfunctioning.
Action: Contact Dell
technical support to
replace the controller
memory.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2060
753
Table 3-4. Storage Management Messages