218 Storage Management Message Reference
2367 Rebuild is not
possible
because
mixing of
different
media type
(SSD/HDD)
and bus
protocols
(SATA/SAS) is
not supported
on the same
virtual disk.
Warning /
Non-critical
Cause: The physical
disk is using an
incompatible
technology.
Action: All physical
disks in the virtual disk
must use the same
technology. You cannot
use both SAS and SATA
physical disks in the
same virtual disk.
Remove the physical
disk and insert a new
physical disk that uses
the correct technology.
If the rebuild does not
start automatically after
you have inserted a
suitable physical disk,
then run the Rebuild
task.
Clear Alert:
None
Related
Alert
Number:
2326
LRA
Number:
2070
903
2368 The SCSI
Enclosure
Processor
(SEP) has been
rebooted as
part of the
firmware
download
operation and
is unavailable
until the
operation
completes.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None.
Clear Alert:
None
Related
Alert
Number:
2049, 2052,
2162, 2292
LRA
Number:
None
851
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vue de la page 217