Storage Management Message Reference 91
2094 Predictive
Failure
reported.
Warning /
Non-critical
Cause: The physical
disk is predicted to fail.
Many physical disks
contain Self Monitoring
Analysis and Reporting
Technology (SMART).
When enabled, SMART
monitors the health of
the disk based on
indications such as the
number of write
operations that have
been performed on the
disk.
Action: Replace the
physical disk. Even
though the disk may
not have failed yet, it is
strongly recommended
that you replace the
disk.
If this disk is part of a
redundant virtual disk,
perform the Offline
task on the disk; replace
the disk; the rebuild
starts automatically.
NOTE: If you put the
drive in a different slot,
you need to assign it as a
hot spare for the rebuild
to start automatically.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2070
903
Table 3-4. Storage Management Messages