Chapter 10 Getting Information Logs and Reports
Viewing FC I/O Blade Port Information
Dell PowerVault ML6000 User’s Guide 198
Actual Speed — Negotiated speed of the port: 1 Gb/s, 2 Gb/s, or
4 Gb/s. If the port is not in a ready state, “N/A” displays.
Actual Loop ID — Negotiated loop ID of the port: 0–125. On the Web
client, if the port connection type is Point to Point, or if the port is not
in a ready state, “N/A” displays. On the operator panel, if the port is
not in a ready state, “N/A” displays.
Requested Speed — Requested speed of the port: Auto, 1 Gb/s,
2 Gb/s, 4 Gb/s, or 8 Gb/s (Web client only).
Requested Loop ID — Requested loop ID of the port: Auto or 0–125
(Web client only).
Framesize — Framesize setting of the port: 528, 1024, or 2048.
Mode — Mode of the port: Public or Private.
Role — Role of the port: Target (ports 1–2) or Initiator (ports 3–6).
Connection — Connection type of the port: Loop, Point to Point, or
Loop Preferred.
For information about configuring FC I/O blade ports, see Configuring
FC I/O Blade Ports on page 110.
The paths to open the appropriate screens are as follows:
From the Web client, select Tools > I/O Blade Port Info.
From the operator panel, select Tools > Blade Info > Port Info.