Dell Chassis Management Controller Version 4.50 Guide de l'utilisateur Page 201

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 428
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 200
cfgChassisPowerStatus (Read Only)
Description
Indicates the power status of the chassis.
Legal Values
1 — (other)
2 — (unknown)
3 — (OK)
4 — (noncritical)
5 — (critical)
6 — (nonrecoverable)
Default
None
cfgChassisRedundantState (Read Only)
Description
Enables or disables power redundancy for the chassis.
Legal Values
0 — (none)
1 — (full)
Default
None
cfgChassisPowerCap (Read or Write)
Description
Indicates the maximum power consumption limit (in watts) for the entire chassis. The command
generates an error if server throttling is necessary to achieve the power goal based on the value for
this setting.
Legal Values
2715–16685 watts
Default
16685 watts
cfgChassisPowerCapF (Read or Write)
Description
Indicates the maximum power consumption limit (in watts) for the entire chassis. Use
cfgChassisPowerCapF when power consumption changes regardless of whether server
throttling is required. This command generates an error if the value for this setting is lower than the
minimum power required for the chassis configuration.
Legal Values
271–16685 watts
Default
16685 watts
cfgChassisPowerCapBTU (Read or Write)
Description
Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. The command
generates an error if server throttling is necessary to achieve the power goal based on the value for
this setting.
Legal Values
9264–56931 BTU/hr
201
Vue de la page 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 427 428

Commentaires sur ces manuels

Pas de commentaire