Dell Chassis Management Controller Version 4.50 Guide de l'utilisateur Page 278

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 428
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 277
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
iDRAC.IPMILan
To configure IPMI over LAN of the system, use the objects in this group.
iDRAC.IPMILan.AlertEnable (Read or Write)
Description Enables or disables global email alerting.
Legal Values
0 — Disabled
1 — Enabled
Default Value 0 — Disabled
Write Privilege Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
iDRAC.IPMILan.CommunityName (Read or Write)
Description
Specifies the SNMP community name for traps.
Legal Values
String of up to 18 ASCII characters
Default Value
Public
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
iDRAC.IPMILan.Enable (Read or Write)
Description
Enables or disables the IPMI over LAN interface.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — Disabled
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
278
Vue de la page 277
1 2 ... 273 274 275 276 277 278 279 280 281 282 283 ... 427 428

Commentaires sur ces manuels

Pas de commentaire