System.Power.EnergyConsumption.Clear (Read or Write)
Description
Clears the cumulative power consumption timestamps.
Legal Values
1
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
System.Power.EnergyConsumption.StarttimeStamp (ReadOnly)
Description
Displays the Timestamp of the cumulative power consumption.
Legal Values
String of up to 254 ASCII characters
Default Value
Timestamp of the cumulative power consumption.
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Write Privilege
None
System.Power.Hotspare.Enable (Read or Write)
Description Enables hot-spare functionality for the primary PSU selection. For more information about hot-
spare, see the iDRAC7 User’s Guide available at www.dell.com/esmmanuals.
NOTE: This object is supported only for iDRAC on Rack and Tower servers.
Legal Values
0 — Disabled
1 — Enabled
Default Value 1 — Enabled
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.Hotspare.PrimaryPSU (Read or Write)
Description
Represents the primary PSU selection.
NOTE: This object is supported only for iDRAC on Rack and Tower servers.
Legal Values
1 — PSU1
2 — PSU2