NIC.NICPartitioningConfig.NumberPCIEFunctionsSupported (Read Only)
Description
Indicates the number of physical PCIe functions supported on this port.
Legal Values
Values: 1–65535
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
NIC.VndrConfigGroup
The objects in this group manage the vendor configuration settings.
NIC.VndrConfigGroup.BusDeviceFunction (Read Only)
Description
Indicates the BIOS assigned PCIe.
Legal Values
String of up to 8 characters
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
NIC.VndrConfigGroup.BlnkLeds (Read or Write)
Description
Identifies the physical network port by blinking the associated LED.
Legal Values
Values: 0–15
Default Value
15
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
NIC.VndrConfigGroup.ChipMdl (Read Only)
Description
Indicates the chip type or revision.
Legal Values
None
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
412