BIOS.SerialCommSettings
To manage the serial port settings, use the objects in the group.
BIOS.SerialCommSettings.ConTermType (Read or Write)
Description
Configures the remote console's terminal type.
Legal Values
Vt100Vt220
Ansi
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.SerialCommSettings.ExtSerialConnector (Read or Write)
Description
Associate the External Serial Connector to Serial 1 or Serial 2 or Remote Access Device.
Legal Values
Serial1
Serial2
RemoteAccDevice
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.SerialCommSettings.FailSafeBaud (Read or Write)
Description
BIOS attempts to determine the baud rate automatically. This fail-safe baud rate is used only if the
attempt is unsuccessful.
Legal Values
115200
57600
19200
9600
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
376