Default
1
cfgIpmiSerialHandshakeControl (Read or Write)
Description
Enables or disables the IPMI terminal mode handshake control.
Legal Values
0(FALSE)
1 (TRUE)
Default
1
cfgIpmiSerialNewLineSequence (Read or Write)
Description
Specifies the new line sequence specification for the IPMI serial interface.
Legal Values
0 — None
1 — CR-LF
2 — NULL
3 — CR
4 — LF-CR
5 — LF
Default
1
cfgIpmiSerialLineEdit (Read or Write)
Description
Enables or disables line editing on the IPMI serial interface.
Legal Values
0(FALSE)
1(TRUE)
Default
1
cfgIpmiSerialInputNewLineSequence (Read or Write)
Description
Specifies the input new line sequence specification for the IPMI serial interface.
Legal Values
1 — ENTER
2 — NULL
Default
1
cfgSmartCard
This group specifies properties used to support access to iDRAC using a smart card. This group is applicable only for
iDRAC.
The following sections provide information about the objects in the cfgSmartCard group.