This object is applicable only for iDRAC.
Legal Values
Not applicable
Default
<blank>
cfgServerPowerCapEnable (Read or Write)
Description
Enables or disables the user specified power budget threshold.
This object is Read only for iDRAC Enterprise on Blade Servers.
Legal Values
0 — Disables the user specified power budget threshold
1 — Enables the user specified power budget threshold
Default
1
cfgServerMinPowerCapacity (Read Only)
Description
Represents the minimum server power capacity on a blade based on the current component
inventory.
This object is applicable only for iDRAC.
Legal Values
Not applicable
Default
<blank>
cfgServerMaxPowerCapacity (Read Only)
Description
Represents the maximum server power capacity based on the current component consumption. This
object is applicable only for iDRAC.
Legal Values
Not applicable
Default
<blank>
cfgServerPeakPowerConsumption (Read Only)
Description
Represents the servers maximum power consumption until the current time.
This object is applicable only for iDRAC.
Legal Values
Not applicable
Default
Peak power consumption of the server
cfgServerPeakPowerConsumptionTimestamp (Read Only)
Description
Specifies time when the maximum power consumption was recorded.
This object is applicable only for iDRAC.
Legal Values
A string of up to 32 characters.
Default
Timestamp of the peak power consumption of the server.