• To display entire information log.
racadm getactiveerrors -s info
Module ID = server-1
Severity = Critical
Message = A fabric mismatch deteceted for mezzanine card B1.
Module ID = ps-1
Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected
between system BIOS in slot 4 and CMC.
getarraycfg
Description This command is applicable only for CMC.
To display the storage array properties and configuration status, run this command.
Synopsis
getarraycfg -m <module> [-s]
Input
• -m — The valid value for —m <module> is server–n, where n = 1–16.
• -s — Query for current storage configuration process status.
Output Array configured properties for:
• Member Name
• Member IP
• Group Name
• Group IP
• Fabric Selection
<module> configuration completed successfully.
Example
• Get the configured storage array properties from server–3.
racadm getarraycfg -m server-3
• Query for current storage configuration process status on server–3.
racadm getarraycfg -m server-3 -s
getassettag
Description
Displays the asset tag for the chassis.
This subcommand is applicable only for CMC.