Dell Chassis Management Controller Version 4.50 Guide de l'utilisateur Page 338

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 428
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 337
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express (For Blades) or iDRAC7 Enterprise
Dependency
None
iDRAC.VirtualConsole.Timeout (Read or Write)
Description
Defines the idle timeout in seconds for the virtual console.
Legal Values
Integral values: 60–10800
Default Value
1800
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express (For Blades) or iDRAC7 Enterprise
Dependency
None
iDRAC.VirtualMedia
The objects in this group enable you to manage virtual media configuration parameters of iDRAC.
iDRAC.VirtualMedia.Attached (Read or Write)
Description
Used to attach virtual devices to the system using the USB bus.
Legal Values
0 — Detached
1 — Attached
2 — AutoAttach
Default Value
2 — AutoAttach
Write Privilege
Virtual Media
License
Required
iDRAC7 Express (For Blades) or iDRAC7 Enterprise
Dependency
None
iDRAC.VirtualMedia.BootOnce (Read or Write)
Description
Enables or disables the virtual media boot once feature of the iDRAC.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — Disabled
Write Privilege
Virtual Media
338