Chapter 12 Installing, Removing, and Replacing
Adding, Removing, and Replacing FC I/O Blades
Dell PowerVault ML6000 User’s Guide 368
7 Make sure cover plates are installed over any unused bays in the 9U
Library Expansion Module.
8 Cable the library as described in Cabling Libraries With Fibre
Channel Tape Drives Connected to Fibre Channel I/O Blades on
page 228.
9 Save the library configuration (see Saving the Library Configuration
on page 385).
Removing an FC I/O
Blade 12
These instructions explain how to remove an FC I/O blade from your
library. You can remove an FC I/O blade while the library is powered on.
Required tools: None
1 Access the back of the expansion module containing the FC I/O
blade.
2 Tag and disconnect all FC cables from the FC I/O blade.
3 Lift the latch hooks out of the locked position and push them up. You
will feel the FC I/O blade unplug from the expansion module’s
backplane.
4 Continue lifting on the latch hooks until the blade is totally
unplugged from the backplane.
5 Slide the FC I/O blade out of the expansion module.
Caution: Bays that are not populated with blades must
contain a cover plate. If the cover plate is not
installed, FC I/O blade temperature errors will
occur.
Note: The library will generate a RAS ticket when you remove the
I/O blade. If you do not want the library to generate a RAS
ticket, you can power down the I/O blade before removing it.
See Controlling FC I/O Blade Power on page 187.
Caution: Handle the FC cables with care. They will be damaged
if they are bent at more than a four inch arc.
Vue de la page 367