Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guide de l'utilisateur Page 121

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 931
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 120
CMC8534
Message Unable to turn on the server
arg1
because the power requirement request exceeds the power
cap value.
Arguments
arg1 =
slot number
Detailed
Description
Unable to turn on the server specified in the message, because the available power is lesser
than the requested power.
Recommended
Response Action
In the CMC Web interface, verify the available power and server power requirements. If
sufficient power is available, retry the operation. Otherwise, increase the power cap value.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 2 (Warning)
Trap/EventID 2546
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8535
Message Unable to turn on High Power Management for the server
arg1
Arguments
arg1 =
slot number
Detailed
Description
Unable to turn on the server specified in the message because of an internal CMC error.
Recommended
Response Action
Reboot CMC and retry the operation. If the issue persists, reseat the server and retry the
operation.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID 8689
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log