Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guide de l'utilisateur Page 325

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 931
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 324
18
LC Event Messages
LC054
Message Unable to write to the network share.
Detailed
Description
The network share may be read-only or it may not have sufficient space for the export
operation..
Recommended
Response Action
Verify the network share is not read-only and has sufficient space for exporting, then retry the
operation.
Category Configuration
SubCategory LC = Lifecycle Contr
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
LC055
Message Operation failed due to invalid attribute array.
Detailed
Description
The operation failed because the number of AttributeName input parameters provided to the
method exceeded the number of attributes available in iDRAC.
Recommended
Response Action
Retry the operation with an input parameter array that matches the available attributes in
iDRAC.
Category Configuration
SubCategory LC = Lifecycle Contr
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
325
Vue de la page 324
1 2 ... 320 321 322 323 324 325 326 327 328 329 330 ... 930 931

Commentaires sur ces manuels

Pas de commentaire