Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guide de l'utilisateur Page 468

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 931
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 467
arg2 =
physical disk
Detailed
Description
A user aborted an ongoing copyback operation. The operation did not complete.
Recommended
Response Action
Re-issue the command.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR81
Message Microcode update started on
arg1
.
Arguments
arg1 =
physical disk
Detailed
Description
The physical disk firmware update operation has started.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR82
Message
arg1
security was activated.
468
Vue de la page 467
1 2 ... 463 464 465 466 467 468 469 470 471 472 473 ... 930 931

Commentaires sur ces manuels

Pas de commentaire