VLT Event Messages
VLT0300
Message CPU
arg1arg2
voltage is less than the lower warning threshold.
Arguments
arg1 =
number
arg2 =
name
Detailed
Description
Low voltages may be the result of a problem with the voltage regulator or a problem with the
processor. The low voltage may cause the processor to fail to operate.
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT0301
Message CPU
arg1arg2
voltage is less than the lower critical threshold.
Arguments
arg1 =
number
arg2 =
name
Detailed
Description
Low voltages may be the result of a problem with the voltage regulator or a problem with the
processor. When the critical threshold is crossed, the processor will fail to operate. The
system may power down.
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.