Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guide de l'utilisateur Page 366

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 931
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 365
LCD Message Multi-bit memory error on <location>. Reseat memory
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
MEM0002
Message Parity memory errors detected on a memory device at location
arg1
.
Arguments
arg1 =
location
Detailed
Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended
Response Action
Re-install the memory component. If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health
SubCategory MEM = Memory
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
MEM0003
Message Stuck bit memory error detected on a memory device at location
arg1
.
Arguments
arg1 =
location
Detailed
Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended
Response Action
Re-install the memory component. If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health
SubCategory MEM = Memory
Severity Severity 1 (Critical)
366
Vue de la page 365
1 2 ... 361 362 363 364 365 366 367 368 369 370 371 ... 930 931

Commentaires sur ces manuels