Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR33
Message A dedicated hot spare has been removed.
arg1
Arguments
arg1 =
PD Name
Detailed
Description
The controller cannot to communicate with a disk that is assigned as a global hot spare. The
disk either failed or was removed. There may also be a bad or loose cable.
Recommended
Response Action
Verify that the disk is healthy and installed. Check the cables. Refer to the product
documentation and see the Cables Attached Correctly section for more information on
checking the cables. If necessary, replace the disk and reassign the global hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR34
Message A dedicated hot spare has been automatically unassigned.
arg1
Arguments
arg1 =
PD Name
Detailed
Description
The hot spare is no longer required because the virtual disk it was assigned to has been
deleted.