The discovery process for PCIE adapters was unable to allocate the power required to power
on the PCIE adapters
Recommended
Response Action
Raise power cap or add power supply
Category Configuration
SubCategory IOV = IO Virtualization
Severity Severity 2 (Warning)
Trap/EventID 10746
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
IOV117
Message
arg1arg2
.unassigned from server-
arg3
.
Arguments
arg1 =
PCIE Slot/PERC VA
arg2 =
slot/VA number
arg3 =
server numer
Detailed
Description
A PCIE Slot or PERC Virtual Adapter has been unassigned from a server
Recommended
Response Action
No response action is required.
Category Configuration
SubCategory IOV = IO Virtualization
Severity Severity 3 (Informational)
Trap/EventID 10747
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE