Severity Severity 1 (Critical)
Trap/EventID 4329
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL48
Message A foreign configuration was detected on
arg1
.
Arguments
arg1 =
controller name
Detailed
Description
The controller has physical disks that were moved from another controller or have been
removed and replaced on the current configuration. These physical disks contain virtual disks
that were created on the current or other controller. See the storage hardware documentation
for Import Foreign Configuration and Clear Foreign Configuration for more information. Foreign
configuration is seen when a controller is replaced.
Recommended
Response Action
Import or clear the detected foreign configuration using a configuration tool or utility.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)
Trap/EventID 4331
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL49
Message The NVRAM has corrupted data on
arg1
.
Arguments
arg1 =
Controller name
Detailed
Description
The NVRAM has corrupted data. This may occur after a power surge, a battery failure, or for
other reasons. The controller is reinitializing the NVRAM.