Vue de la page 864
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR15
Message Initialization of
arg1
was cancelled.
Arguments
arg1 =
virtual disk
Detailed
Description
The initialization operation could not be completed. This may be due to a user action or a
physical disk failure.
Recommended
Response Action
If a physical disk failed, then replace the physical disk. Restart the virtual disk initialization.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID 4355
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR16
Message Consistency check of
arg1
failed.
Arguments
arg1 =
virtual disk
Detailed
Description
A physical disk included in the virtual disk failed or there is an error in the parity information. A
failed physical disk causes errors in parity information.
Recommended
Response Action
Check that all the physical disks of the virtual disk are in a healthy condition. Replace any disks
that are not healthy and restart the operation. If this is not the problem, delete the virtual disk
and restore the data to the disk from a backup copy.
Category Storage
SubCategory VDR = Virtual Disk