6
CBL Event Messages
CBL8500
Message SAS cable
arg1
to expander
arg2
is not connected.
Arguments
arg1 =
cable id
arg2 =
expander id
Detailed
Description
SAS cables are not connected to the expander correctly.
Recommended
Response Action
Check whether or not the SAS cables are connected to the expander. Reconnect the cables
and rety the operation.
Category Storage
SubCategory CBL = Cable
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CBL8501
Message SAS cable
arg1
is connected to the incorrect expander.
Arguments
arg1 =
cable id
Detailed
Description
The SAS cable identified in the message is not connected to the correct expander.
Recommended
Response Action
Reconnect the SAS cable to the correct expander and retry the operation.
Category Storage
SubCategory CBL = Cable
99