Vue de la page 297
Severity Severity 2 (Warning)
Trap/EventID 2554
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LCD;#LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
IOV105
Message Unable to manage PCIE device
arg1
located in
arg2arg3
.
Arguments
arg1 =
device name
arg2 =
slot type
arg3 =
slot number
Detailed
Description
An error by the IOV slot management detected an error which may prevent the physical
assignment/unassignment or power off of a slot. The errors may be caused by PCIE training
timeouts or false hot plug signals. Only Dell approved adapters are supported.
Recommended
Response Action
Make sure that supported adapters are used and installed correctly in the PCIe slot.
Category System Health
SubCategory IOV = IO Virtualization
Severity Severity 2 (Warning)
Trap/EventID 2554
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LCD;#LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
IOV106
Message Unable to power on PCIe device
arg1
in
arg2arg3
.
Arguments
arg1 =
device name
arg2 =
slot type
arg3 =
slot number
298