Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guide de l'utilisateur Page 223

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 931
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 222
ENC23
Message
arg1
Bad PHY
arg2
Arguments
arg1 =
Enclosure Name
arg2 =
args
Detailed
Description
There is a problem with a physical connection or PHY.
Recommended
Response Action
Contact the Dell Technical Support at support.dell.com.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
Trap/EventID 4337
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
ENC24
Message Communication with
arg1
is intermittent.
Arguments
arg1 =
enclosure name
Detailed
Description
The controller is not receiving a consistent response from the enclosure. There could be a
firmware problem or an invalid cabling configuration. If the cables are too long, they degrade
the signal.
Recommended
Response Action
Power down all enclosures attached to the system and reboot . If the problem persists,
upgrade the firmware to the latest supported version. Verify the cable configuration is valid.
See the storage hardware documentation for valid cabling configurations.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
Trap/EventID 4337
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
223
Vue de la page 222
1 2 ... 218 219 220 221 222 223 224 225 226 227 228 ... 930 931