Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWU8519
Message The firmware update operation of the iDRAC on the server in slot
arg1
is stopped. The Image file
is corrupted.
Arguments
arg1 =
slot number
Detailed
Description
The iDRAC firmware update operation was stopped, because the Image file is corrupted.
Recommended
Response Action
Reacquire the Image file from the original source, and then retry the operation.
Category Updates
SubCategory SWU = Software Change
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWU8520
Message The firmware update operation of the iDRAC on the server in slot
arg1
is not successful.
Arguments
arg1 =
slot number
Detailed
Description
The firmware update operation of the iDRAC identified in the message is not successful.
Recommended
Response Action
Reacquire the Image file from the original source, and then retry the operation.
Category Updates
SubCategory SWU = Software Change
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.