Category System Health
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR1001
Message Fault detected on drive
arg1
in disk drive bay
arg2
.
Arguments
arg1 =
number
arg2 =
bay
Detailed
Description
The controller detected a failure on the disk and has taken the disk offline.
Recommended
Response Action
Remove and reseat the failed drive. If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Fault detected on drive <number> in disk drive bay <bay>. Check drive.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR1016
Message Drive
arg1
is removed from disk drive bay
arg2
.
Arguments
arg1 =
number
arg2 =
bay